ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "000c1a4a-3c99-47a9-a465-ebd00337e011"}, "_deposit": {"created_by": 15, "id": "120", "owners": [15], "pid": {"revision_id": 0, "type": "depid", "value": "120"}, "status": "published"}, "_oai": {"id": "oai:iuhw.repo.nii.ac.jp:00000120", "sets": ["19"]}, "author_link": ["837", "836", "838", "840", "839", "835"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-07-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "23", "bibliographicPageStart": "18", "bibliographicVolumeNumber": "10", "bibliographic_titles": [{"bibliographic_title": "国際医療福祉大学紀要"}, {"bibliographic_title": "Bulletin of International University of Health and Welfare", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "腹横筋が脊椎の安定性に重要な役割を果たしてることが指摘されている。しかし,腹横筋は身体深部に位置しており,客観的な身体的検査が困難である。本研究は,圧バイオフィードバック装置と超音波診断装置を用いて,腹横筋の機能評価を試み,臨床応用のための基礎的知見を得ることを目的とした。結果は,腹横筋の選択的収縮が得られた群と得られなかった群の圧変化(平均±標準偏差)は,それぞれ-4.2±2.0mmHg(n=10),0.1±3.2mmHg(n=12)であり,両群間に統計的有意差を認めた(p\u003c0.05)。したがって,圧バイオフィードバック装置と超音波診断装置を用いることによって,腹横筋の機能を評価できる可能性が示唆された。", "subitem_description_type": "Abstract"}]}, "item_10002_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "It is pointed out that the transeversus abdominis muscle plays an important role for the spinal stabilization. Because transversus abdominis muscle lies in the deeper part of the body, it is difficult to do the objective physical examination. The purpose of this study was to try the functional evaluation of the transeversus abdominis muscle through the ultrasonic diagnostic imaging equipment and the pressure bio-feedback equipment in order to get the basic knowledge for the clinical application. Based on these results, the possibility to be able to evaluate the function of the transeversus abdominis muscle using ultrasonic diagnostic imaging equipment and pressure bio-feedback equipment.", "subitem_description_type": "Other"}]}, "item_10002_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "838", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "HIGUCHI, Yoshihide"}]}, {"nameIdentifiers": [{"nameIdentifier": "839", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "SAITO, Akihiko"}]}, {"nameIdentifiers": [{"nameIdentifier": "840", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "ARAI, Shoichi"}]}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "国際医療福祉大学"}]}, "item_10002_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN1059280X", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13424661", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "樋口, 善英"}, {"creatorName": "ヒグチ, ヨシヒデ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "835", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "齋藤, 昭彦"}, {"creatorName": "サイトウ, アキヒコ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "836", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "新井, 正一"}, {"creatorName": "アライ, ショウイチ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "837", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-05-22"}], "displaytype": "simple", "download_preview_message": "", "file_order": 0, "filename": "10_2(18-23p).pdf", "filesize": [{"value": "471.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 471400.0, "url": {"label": "本文(PDF)", "url": "https://iuhw.repo.nii.ac.jp/record/120/files/10_2(18-23p).pdf"}, "version_id": "b674b988-932f-4230-841c-63d07e37a04f"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "腹横筋", "subitem_subject_scheme": "Other"}, {"subitem_subject": "圧バイオフィードバック装置", "subitem_subject_scheme": "Other"}, {"subitem_subject": "機能評価", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Transversus Abdominis Muscle", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Pressure Bio-Feedback Equipment", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Functional Evaluation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "圧バイオフィードバック装置と超音波診療装置を用いた腹横筋の機能評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "圧バイオフィードバック装置と超音波診療装置を用いた腹横筋の機能評価"}, {"subitem_title": "The functional evaluation of the transeversus abdominis muscle through the ultrasonic diagnostic imaging equipment and the pressure bio-feedback equipment", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "15", "path": ["19"], "permalink_uri": "https://iuhw.repo.nii.ac.jp/records/120", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-05-22"}, "publish_date": "2012-05-22", "publish_status": "0", "recid": "120", "relation": {}, "relation_version_is_last": true, "title": ["圧バイオフィードバック装置と超音波診療装置を用いた腹横筋の機能評価"], "weko_shared_id": -1}
  1. 国際医療福祉大学紀要
  2. 第10巻第2号

圧バイオフィードバック装置と超音波診療装置を用いた腹横筋の機能評価

https://iuhw.repo.nii.ac.jp/records/120
https://iuhw.repo.nii.ac.jp/records/120
82ba442f-5268-46ca-83bb-60709ab5562f
名前 / ファイル ライセンス アクション
10_2(18-23p).pdf 本文(PDF) (471.4 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2012-05-22
タイトル
タイトル 圧バイオフィードバック装置と超音波診療装置を用いた腹横筋の機能評価
タイトル
言語 en
タイトル The functional evaluation of the transeversus abdominis muscle through the ultrasonic diagnostic imaging equipment and the pressure bio-feedback equipment
言語
言語 jpn
キーワード
主題Scheme Other
主題 腹横筋
キーワード
主題Scheme Other
主題 圧バイオフィードバック装置
キーワード
主題Scheme Other
主題 機能評価
キーワード
言語 en
主題Scheme Other
主題 Transversus Abdominis Muscle
キーワード
言語 en
主題Scheme Other
主題 Pressure Bio-Feedback Equipment
キーワード
言語 en
主題Scheme Other
主題 Functional Evaluation
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ departmental bulletin paper
著者 樋口, 善英

× 樋口, 善英

WEKO 835

樋口, 善英

ja-Kana ヒグチ, ヨシヒデ

Search repository
齋藤, 昭彦

× 齋藤, 昭彦

WEKO 836

齋藤, 昭彦

ja-Kana サイトウ, アキヒコ

Search repository
新井, 正一

× 新井, 正一

WEKO 837

新井, 正一

ja-Kana アライ, ショウイチ

Search repository
著者別名
姓名 HIGUCHI, Yoshihide
著者別名
姓名 SAITO, Akihiko
著者別名
姓名 ARAI, Shoichi
抄録
内容記述タイプ Abstract
内容記述 腹横筋が脊椎の安定性に重要な役割を果たしてることが指摘されている。しかし,腹横筋は身体深部に位置しており,客観的な身体的検査が困難である。本研究は,圧バイオフィードバック装置と超音波診断装置を用いて,腹横筋の機能評価を試み,臨床応用のための基礎的知見を得ることを目的とした。結果は,腹横筋の選択的収縮が得られた群と得られなかった群の圧変化(平均±標準偏差)は,それぞれ-4.2±2.0mmHg(n=10),0.1±3.2mmHg(n=12)であり,両群間に統計的有意差を認めた(p<0.05)。したがって,圧バイオフィードバック装置と超音波診断装置を用いることによって,腹横筋の機能を評価できる可能性が示唆された。
内容記述
内容記述タイプ Other
内容記述 It is pointed out that the transeversus abdominis muscle plays an important role for the spinal stabilization. Because transversus abdominis muscle lies in the deeper part of the body, it is difficult to do the objective physical examination. The purpose of this study was to try the functional evaluation of the transeversus abdominis muscle through the ultrasonic diagnostic imaging equipment and the pressure bio-feedback equipment in order to get the basic knowledge for the clinical application. Based on these results, the possibility to be able to evaluate the function of the transeversus abdominis muscle using ultrasonic diagnostic imaging equipment and pressure bio-feedback equipment.
書誌情報 国際医療福祉大学紀要
en : Bulletin of International University of Health and Welfare

巻 10, 号 2, p. 18-23, 発行日 2005-07-31
出版者
出版者 国際医療福祉大学
ISSN
収録物識別子タイプ ISSN
収録物識別子 13424661
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN1059280X
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 09:25:53.744460
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3